AL-DSC/OIT and TGA devices are advanced systems developed for analyzing thermal stability, oxidation resistance, and material composition. Fully compliant with ISO EN 11357 standards.
Standards:
Compliant with ISO EN 11357-1, 11357-2, 11357-3, and 11357-6 standards, our thermal analysis instruments measure changes in physical properties of materials when subjected to a controlled temperature program. These techniques are widely used in both quality control and research and development of various industrial products such as polymers, pharmaceuticals, clays and minerals, metals, and alloys.
Oxidation Induction Time (OIT) is the period from the first exposure to oxygen until the onset of oxidation. The AL DSC / OIT instrument accurately measures this time, providing critical data on thermal stability, crystallinity, melting point, and phase transitions.
The TGA instrument is a quantitative analysis method that measures the weight changes of a sample as a function of temperature. These changes typically result from the breaking of physical or chemical bonds in a nitrogen or argon atmosphere.
These advanced thermal analysis instruments are essential tools for material research, industrial quality control processes, and product development. Their high precision and reliability ensure superior performance in analyzing oxidation resistance, thermal degradation, and phase transitions.
Standards:
Alarge DSC/OIT testing devices offer high accuracy, reliability, and long service life in industrial quality control processes.




Data transmission speeds at the microsecond level enable instantaneous detection of even the smallest changes in thermal events. This structure allows for the highly accurate identification of critical peaks and rapid phase transitions.


| Specification | Value |
|---|---|
| Operating Temperature | 25°C – 350°C |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | 0.1°C |
| Temperature Control | Digital PID |
| Maximum Sample Amount | 17 mg |
| Heating Rate | 5–20 °C/min |
| Calorimeter Accuracy | < ±0.3% |
| Calorimeter Sensitivity | 0.35 mW |
| Control Screen | 7″ Touchscreen |
| Dimensions | 600 × 600 × 170 mm |
| Net Weight | 21.5 kg |
| Power Consumption | 220V 50–60 Hz |
| Required Gases | Nitrogen Gas, Oxygen Gas (Ultra High Purity) |
The product is valid for 2 years starting from the delivery date.
For your technical support requests, simply contacting us is sufficient. Our expert team will strive to resolve your issue as quickly as possible through remote connection or phone support. If the problem cannot be resolved remotely, our technical team will be dispatched for on-site intervention. This ensures that your device is restored to working condition as swiftly as possible.
The installation and activation of the device you purchased are carried out in your working environment by our expert technical team. After the installation, comprehensive training is provided to your user personnel for the correct and efficient use of the device. This service ensures that you can use all the device’s functions safely and effectively.
To ensure the device operates efficiently and has a long lifespan, regular maintenance is essential. This includes tasks such as cleaning, checking connections, software updates, and calibration. It is recommended to perform maintenance at the intervals specified in the user manual. If desired, you can seek professional support from our technical service for maintenance tasks.
To ensure the device’s accuracy, calibration must be performed at regular intervals. Professional calibration is recommended every 6 months.
If you still have unanswered questions, please don’t hesitate to contact us. We are happy to provide any additional information you need and are always ready to help!